Putty pads8/2/2023 ![]() Pack putty into the inside of conduit fittings to prevent the passage of smoke or sound. Honeywell Thermally Conductive Putty Pads provide high thermal performance and solid thermal reliability. Trim excess at corners and apply to conduit fittings connected to the box ![]() Press pad to surface of top, bottom, and sides of box Cut slits in pad to fit around conduits or cable. If membrane is to be installed after pad installation, overlap front edge of box so that putty will be compressed around edges of box as wallboard is installed. If wall membrane is in place, pack putty into gaps between box and gypsum board slightly overlapping inner wallboard surface. Acoustic intumescent putty pads are designed for use inside or outside electrical socket boxes to maintain fire and smoke barriers when service holes are cut. Putty pads are sized to cover standard size outlet boxes and are designed to work with sound rated wall assemblies. Working to the opposite side of the box to the edges Putty Pads are available as a 7 x 7 poly release faced pad for. Our 3M Fire Barrier Sealant FD 150+ is a gun-grade, latex-based, elastomeric sealant that cures upon exposure to the atmosphere to form a monolithic flexible. 3M Fire Barrier 1.45-in to 1.45-in H Firestop Caulk/Sealant. ![]() Remove poly liner from one side of the putty padĪlign putty pad to the side of box partially overlapping the stud and adhere. Putty Pads are made from intumescent putty which is primarily used a firestopping product. HydroFlame putty pads are designed to be used in conjunction with metallic or non-metallic electrical box outlets. HOW DO I INSTALL PUTTY PADS ON AN ELECTRICAL BOX? STEP 1: All of our intumescent firestop products expand when heated to cut off the path. The pad is sized to fit a common 1-1/2" deep 4S electrical box. Whether you want a prefabricated firestop solution to get the job done faster on smaller pipes or need something more flexible for piping and electrical boxes, HoldRite HydroFlame intumescent firestop wraps, collars and putty pads provide tried-and-true reliability. Putty Pads are available as a 7" x 7" poly release faced pad for protection of recessed electrical boxes and as a through-penetration sealant. Required by Building Codes in rated partitions where horizontal separation of opposite facing electrical boxes is under 24 inches.Putty Pads are made from intumescent putty which is primarily used a firestopping product.Putty pads are UL fire rate and can be used in fire rated walls. ![]() If you’re putting in a new wall, putty pads are a relatively inexpensive and effective way to reduce sound transmission. These pads are molded around the boxes to ensure your wall retains its proper STC performance.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |